Dec 26, 2009
Season greetings from RBF
Hope you guys had a great christmas. Personally I had one of the better ones this year, and a contributing factor was some pretty neat gifts (which are chemistry related).
First up, my gorgeous girlfriend gave me a copy of Julia Child's 'Mastering the art of French cooking'. As Child explains herself in the introduction, this is not merely a cookbook but a textbook on how to cook. What I like about it is Child's philosophy which comes out through her book: that cooking is an science as well as an art, in that it should be reproducible given the right technique is used, a philosophy that I can appreciate as an organic chemist. (This is compared to Jamie Oliver's 'just bang it in the pot' sort of style. This probably reflects my chemistry style: I like things to be done 'properly', rather than being a maverick). You might be wondering why I'm talking about cooking in a chemistry blog, but as we all know, all good chemists are good cooks (not trying to imply that I'm either the former or the latter!), so there's the link.
My second chemistry related christmas gift is this truly stylish shirt from the folks at webelements.com:
This one is from my brother, worn today with pride at the Boxing day sales. If you haven't already, check out some of the other stuff they sell at webelements. Some of the stuff is truly inspired COOLNESS, but probably still not as cool as the Corey mug.
Anyway that's all from me. Enjoy the rest of the festive season and a HAPPY NEW YEAR to you all from the guys at RBF!
Dec 18, 2009
Hmmmm tasty water...
Reminds me of that time I used triphenylarsine... I had a organostannane and HMPA in that same reaction.
Dec 11, 2009
What the hell does this do?
Dec 10, 2009
When people pretend they know chemistry
I thought I'd google any reviews on these fry pans, and I came across this forum thread. As with a lot of threads, things get off topic, and eventually these guys are engaging in a war of words, each armed with their own arsenal of pseudoscientific jargon and arguments. Fascinated and disgusted, I kept reading, and this post by glenngarden is by far the most ludicrous:
AkChicago, the temperature rating of the Eurolux says it all. It is heat resistant to 1200 deg. C. and the surface is ten times stronger than steel. PTFE breaks down at 500 deg. F. You certainly know the conversion of Fahrenheit to Celcius. C = 5/9 x(F-32). So 500F = 260C. And really we know that PTFE starts to kill birds at much lower temperatures.So Eurolux cookware surface is rated for 1200 Deg. C.
ScanPan pan surface is rated for 260 Deg. C at best. Higher than that it certainly kills the birds. If it kills the birds do you want to use it?As you correctly point out, PTFE is a Flourocarbon: Poly Tetra Flouro Ethylene. Notice the Flourine molecule that's in PTFE. Eurolux doesn't use Flourine molecules. Hey, I think Flourine gas is a quick killer, too. And you should not drink Flouride water or use flouride containing toothpaste either. Flourides are known to cause cancer, too. If you want to find Flouride free toothpaste, just visit your neighborhood healthfood store, Whole Foods, etc.
Carbon is an element, no 12 on the Periodic table. Humans are made from carbon compounds. Diamonds are made from pure carbon depending on the crystal structure. Diamonds are the hardest substance and have the highest melting temperature. Nothing unhealthy about carbon. Lead is also made of carbon, and it's not healthy. But the temperature rating of the Eurolux tells you that the carbon fibers are not lead! However, many carbon containing polymeric compounds are deadly. PTFE/Teflon is known to cause cancer in rodents. Carbon doesn't cause cancer. We are made of carbon. Carbon is healthy. PTFE is a carcinogen. Eurolux is heat resistant to 1200 Deg. C. Scanpan fumes at around 200 deg. C, well below frying temperatures.
If you want to eat healthy, or remove at least one source of carcinogen in your life, stay far away from any PTFE pot or pan. Stay away from ScanPan carcinogenic PTFE pots and pans. Use something healthier.
If you don't want to spend the money (Eurolux is expensive), then use high quality stainless steel. Stainless steel is a healthy cooking surface, non carcinogenic, but the eggs won't slip off the pan. You will have to scrub for 10 minutes. But I'd rather scrub for ten minutes, get some exercise in the process, than get cancer with ScanPan. Wouldn't you?
Where do I start with the problems in that... that PTFE doesn't have any fluorine molecules? Eurolux uses a different type of fluorocarbon as their nonstick agent, but somehow that doesn't possess any 'fluorine molecules'? What does PTFE have to do with fluorine gas? and What does fluorine gas have to do with fluoride toothpaste? I mean, maybe we should stop eating salt because chlorine gas is toxic and sodium reacts violent with water!!!
Humans are made from carbon compounds, ok fine, but I can name in my sleep about fifty carbon compounds that will kill you. Sure carbon is not unhealthy anymore? How does diamond's hardness and melting temperature have anything to do with whether PTFE is toxic? Since when did we learn how to make lead from carbon? But if there's nothing unhealthy about carbon, then why is lead which is supposedly made of carbon unhealthy? The temperature rating of Eurolux tells you that the carbon fibres are not lead? HHHHHHHWAAAT?????
Wow wow wee, carbon doesn't cause cancer... I wish you told me that during that time in the lab when I had to catalogue every chemical in the lab and found that the HMPA bottle's lid was completely cracked. Oh by the way the other element found in PTFE is CARBON.
I'm not too worried about whether the PFTE is going to kill me or not. If you're going to use a nonstick pan, don't expect to use it on high heat. Keep it on medium or low and you'll be fine. For high heat go for a solid metal pan with no organic coating. In any case, how much more toxic things than PFTE have us chemists been exposed to anyway. Bring on the nonstick!
Dec 2, 2009
I hope everyone is setting up their Christmas tree
RBF Teaches: How to perform an extraction
- Make sure the tap is closed and clamp the sep. funnel by the NECK (i.e. the small region where the stopper inserts) don't clamp it anywhere else, it will break.
- Wash your sample into the sep. funnel (usually use both a small amount of the aqueous and the organic solvents AND FOR THE SAKE OF ALL THINGS GOOD AND HOLY USE A FUNNEL).
- Put a stopper on the top of the sep. funnel and place your index finger over the stopper and hold the flask with your dominant hand. Unclamp the sep. funnel and with your index finger still in place invert the funnel.
- Shake the funnel to mix the solvents, don't be a baby about it but don't go overboard - shake too vigourously and you will most likely end up with an emulsion of layers that will take quite a while to seperate. Every 5 shakes or so it is a good idea to point the inverted sep. funnel into the fume hood and open the tap to release the vapour pressure that has undoubtedly formed.
- Once, you feel you have shaken enough, usually after about 20sec you can clamp the flask by the neck again BUT MAKE SURE THE TAP IS CLOSED.
- Then REMOVE THE STOPPER - if you don't the sep. funnel will not pour.
- Allow the layers to seperate nicely and then begin draining the lower layer. As a general rule I usually say "if you want the top layer leave a bit of the bottom layer in the funnel, if you want the bottom layer take a bit of the top through as well". While I know it isn't exactly necessary you often find that that way you don't really start worrying about getting the seperation exact.
- If you were after the top layer then collect this in a different collection flask. Make sure the collection flask is quite a bit larger than the amount of solvent you intend to collect.
- Pour the AQUEOUS layer back into the seperatory funnel (needless to say, if your aqueous layer was the top layer you don't have to drain this first then pour it back in).
- Add again the same amount of organic solvent as in step 2 and repeat the steps 3-9. Do this twice so you have 3 extractions overall.
- It is a good idea to TLC your extracts to make sure you are taking the desired spots through and when they have stopped coming through. A good way to do this is to take a TLC spot from a drop of organic solvent on the tip of the sep. funnel.
- OPTIONAL - sometimes unwanted material may also come through with the organic solvent, in this case a wash of the organic solvent with clean brine or water may remove these impurities. This simply requires you pouring the organic solvent into the emptied sep. funnel and adding the aqueous wash. (PLEASE USE A FUNNEL)
- Once you have collected all of your organic solvent you can add a drying agent to remove any water that may have inadvertantly come through. Usually, sodium or magnesium sulfate works a treat. Simply take your collection flask, which should only be 1/3 full or thereabouts and gently swirl the solution while sprinkling in the drying agent. Swirl the flask for about 1-2min to ensure the water is absorbed by the drying agent. You should see clumping of the drying agent that indicates water is being taken up but once the drying agent stops clumping you should have a dry solution.
- Filter off the drying agent and make sure to wash the filter with more of your organic solvent to ensure all of the extracted compound is taken through. Usually you would filter into a PREWEIGHED round bottom flask of sufficient volume (twice as large RBF as the volume you have) and then place the RBF onto the rotavap to remove the solvent.
- Pump the resultant product down and Bob's your uncle. You may have to run a column on your product after this but any tricky ionic/salt compounds will be removed and you will have at least a crude weight and something to analyse by NMR or GCMS.
- Make sure the tap is closed before you add your solution or turn the sep. funnel upright.
- Use a damn funnel for pouring solvents.
- Hold the sep. funnel stopper with your index finger before you unclamp invert it.
- The sep. funnel should be inverted the entire time it is in your hands.
- Don't shake too hard or you will get an emulsion.
- Remember to release the vapour pressure.
- Make sure the tap is closed before you turn the sep. funnel upright.
- Remove the stopper once you have your sep. funnel clamped.
- Don't add too much drying agent. It is a waste.
- Pre-weigh your RBF!
Nov 30, 2009
RBF Teaches: Column chromatography
- Take a long pasteur pipette and attach a rubber dropper to it.
- Insert it into a column (that looks about the right length and width to fit the silica) and put it in until your fingers (holding the rubber dropper) are at the lip of the column. Mark the tube with a marker pen.
- This is the minimum height that your silica must reach. The maximum height is about 3cm from the bulb (solvent reservoir) of the column (if it has one) or the same distance as in step 2 if it doesn't.
- Pour in the silica dry and tap the column gently to settle the silica. Check the height of the silica if it is above the line in step 2 you are good to go if not just pour in a bit more silica until you reach it. If it is way off grab a different column. (Sometimes you have to make do with what the lab has to offer). I suppose I should mention here that if you have a column that has a glass frit then YAY and if not then you have to stuff some cotton wool in from the top of the column into the bottleneck of the column just above the tap.
- Once you have the right amount of silica to fit the column to the minimum height pour the dry silica into your conical flask.
- Using the solvent system you figured out from your TLC pour enough solvent onto the dry silica and swirl the flask/stir with a clean glass rod until you have a free moving slurry. By this I mean you want the silica to move completely without lumps. In this case more solvent is better than too little as you are going to pour it so think of it like pouring soup (you would find it hard to pour a thick soup right? and yes that is rhetorical)
- MAKE SURE YOUR COLUMN IS (vertically) STRAIGHT (in both dimensions) and the tap is closed. Pour a small amount of the solvent into the column (3-5cm is plenty) and then add a small amount of sand (about 1cm thick) and tap the column to get it to settle nice and flat. Wash any sand that sticks down with a bit more solvent (use a pipette). [MSG edit: Alternatively you could put the sand in first then add solvent so that you don't have to wash down the grains of sand. Give the sand layer a few taps with your hand afterwards to liberate any gas bubbles.]
- ONCE AGAIN, MAKE SURE YOUR COLUMN IS STRAIGHT then pour the slurry (for heaven's sake use a funnel) into the column. [MSG edit: make sure your solvent level in the column is high enough so that the sand layer isn't disturbed when you pour in your silica slurry.]
- Open the tap and pour all your slurry in but don't overfill the column. REMEMBER the tap is open so you will have some solvent dripping through. In this case I usually have my solvent mixture bottle underneath the column but if you haven't poured all the silica into the column you can put this flask under the column collect a bit more solvent then pour it into the top of the column again.
- Once it is all in, gently start tapping the column. I use a piece of metal rod wrapped in rubber hose but you can just use your hand or some rubber tubing. Whatever makes you feel good.
- As I said earlier this is Flash chromatography so you can whip out your gooseneck and attach it to a compressed air line and gently OH SO GENTLY push compressed air into your column forcing the solvent through the silica much faster. I personally keke-clip my gooseneck to the top of the column have a long compressed air line with a three way tubing adapter halfway along that allows me to regulate the flow of air with a thumb gently covering the open port of the three way but MSG likes to regulate the air flow with his hand holding the gooseneck. I like my way for sitting down and I haven't had a problem when I use this correctly but neither has MSG. Too much compressed air into the column is not a good thing! [MSG edit: Running flash columns are one of the safer operations done in an organic lab, but you still have to be careful. One of the obvious dangers is exploding columns (because after all, you are forcing air into a semi-sealed glass tube). So whatever method you choose, make sure you're comfortable with it. Safety first! Personally I regulate airflow with my hand. Apart from the fact that you probably get more tired using this method, it is superior in almost every other way. So even if you find this method more difficult, I would recommend running the column in this way. As a student you're here to learn, and so don't worry about making mistakes or stuffing things up: it's all part of the process!]
- As the solvent is pushed through the silica is also packing into a highly ordered form and if you have done the previous steps correctly the silica should form a flat surface at approximately the mark you made earlier. HOWEVER, you DO NOT want to push all the solvent through, you want to have a good amount of solvent covering the silica at this point. If you see the solvent is running out then use a pipette to add some more, it is ok to shut the tap of the column as well. You may also have some silica stuck to the sides of the column and while it doesn't really matter you can wash this down with a bit of solvent (using a pipette).
- Finally, with about 3cm of solvent remaining above the silica level you can add about 0.5cm of sand to the top of the column (THIS IS OPTIONAL BUT ADVISED). This just prevents the disturbance of the nice flat silica (you want your compounds to all start at the same point as in TLC) when you pour in more solvent. [MSG edit: I usually do this step AFTER loading the column (see below)]
- After adding the MINIMUM amount of solvent necessary to dissolve your sample (generally you use the same solvent as the column but sometimes DCM is necessary) take a tiny amount for TLC comparison. [MSG edit: if you do use DCM, don't be surprised if you don't get as good a separation as you intended. When dissolving your sample, use at least the same amount of solvent as your sample. That is, if you have 1g of sample, use at least 1mL. This is more relevant when you have a liquid as your product. On a volume ratio, if the amount of solvent is less than your sample then technically your solvent is dissolved in your sample rather than the other way round]
- Allow the solvent level in the column to reach the same level as the top of the silica.
- Using a long pasteur pipette very carefully transfer the compound across. (Now do you see why we made the minimum height mark?) It is wise to load the sample on by running it down the side of the column but do this as close to the top of the silica (or the 0.5cm layer of sand if you have it).
- Once you have added all of your sample run the column down to level with the top of the silica once more and rinse your product flask with the solvent.
- Add this to the column again and repeat step 4.
- Very carefully add ~1cm solvent to the top of the column using a clean pipette and repeat step 4 once more.
- Carefully add solvent to the top of your column with a pipette to ~5-10cm then you can try gently running the solvent down the edge of the pipette to prevent the disturbance of the silica.
- Once you have ~25cm of solvent in there you can carefully pour the solvent mixture into the column using a funnel until the column is full.
]
- Open the tap
- Using compressed air you can force the solvent through or simply wait for gravity to do its job. It is important in both these cases that the flow rate remains roughly regular. If you are using compressed air for Flash chromatography a fast flow rate is important for good separation. You want the solvent to be pouring in a continuous flow from the tip of the column not dripping.
- Change your collection vials at about 2/3 full (a rule-o'-thumb is each fraction is half the weight of the silica e.g. 20g silica column = 10mL fractions) and rinse the tip of the column with a small amount of the solvent mixture before exchange (or you can dip the tip of the column in the solvent in the collection vial if it reaches).
- I personally relieve the flow rate when I am exchanging collection vials but like I said the quicker the better.
- Run TLC's on the fractions (for larger columns TLC every 2nd or 3rd fraction to save a bit of time). I generally take 10 fractions then TLC and while the TLC is running I collect another 10. I am spotting the TLC plates while forcing the solvent through the column. (This comes with experience; some people are even more insanely awesome LabChimp)
- Analyse your fractions fully (when you find a spot in your "every 2nd fraction TLC" it is often necessary to test some in between fractions (e.g. spot appears in 8 ends in 12 but need to check 9 and 13) against the reference sample you took) and group similar fractions together.
Nov 24, 2009
One reaction, three bonds
A scheme will probably clear things up:
As the authors describe, what this Pd mediated transformation achieves is a formal [3+2] cycloaddition. It is certainly only a cycloaddition in a formal sense if one takes a look at the mechanism proposed by the authors (which I have no problems with). It's all pretty well established stuff (chloropalladation, reductive elimination etc) as well as based on mechanistic studies (that's the oxypalladation step). I've certainly seen Pd catalysed reaction mechanisms which... let's just say a great deal of Jedi mind tricks will be required for me to accept them.
A bit about the conditions: The catalyst loading is low (1%, no conversion without the presence of catalyst), in a polar solvent (acetic acid or MeCN). The highest yield observed on the model system (in the first scheme) was 83% using MeCN and 3eq of LiCl. Apparently the reaction is not air or moisture sensitive either which is great; using inert gas reaction atmosphere isn't that annoying, but drying and degassing solvents do take up time.
But there are two things I really like about this publication:
1. In one step you form three bonds. Fair enough, only one of them is a C-C bond (Diels-Alder is still king) but you do form two rings. And the C-Cl bond is awesome because...
2. ... the vinyl halide functionality of the product is primed for another Pd catalysed C-C forming reaction. I'm thinking Stille, Heck etc. Now I wonder if you can tweak it so that you can add a stannane in there and do a Stille in the same pot...
Nov 23, 2009
I want a nano-dragster for xmas
So I came across this today in my ASAP feed. It's a sweet nano-dragster with super awesome upgraded front wheels for directional steering. You can like take it off sweet jumps and drive it around and stuff. Oh and if you buy the super awesome scanning electron microscope you may actually see it. AWESOME!
But W did happen to ask me one very simple question, WHY!? Well I will tell you why, because its a nano-dragster that's why! As if you wouldn't want it. It has methyl-scythed-p-carborane front wheels that give it some directionality and HUGE C-60 rear wheels for good traction on GOLD surfaces. ROCK ON!
With the nano-dragster you can even make it do sweet tricks like wobbling the front axle. SUPER COOL! Forget about those old boring normal sized cars or even those sweet mini RC cars. This is the future! I want one for XMAS and so should you!
Nov 19, 2009
Comments Are Back Online
New Moon Buffoon
Nov 16, 2009
Uncle OO's story time: How TLC works
Today I will tell you a great story, of mystery and magic....ok so it's not so much that as chemistry and common sense. Basically, I'm going to give you my patented "How chromatography works" story. Hopefully somewhere along the line some cool cartoons can also be added but for now your imagination will have to suffice.
Ok so I detailed to you the way in which to run a TLC. But now for a nice little explanation of how they work.
Imagine a large forest of trees. This large forest of trees represents the silica on a plate or in a column. Now imagine that this forest (all of these trees are identical and evenly spaced) is very tightly packed all crammed in together. Now imagine you are a really skinny person and your friend is rather large (but for fairness let's say they are muscular). You, being skinny represent a non-polar molecule and your friend represents a polar molecule. You are both at the edge of the forest and want to race through.
Suddenly riot police jump out of nowhere (these riot police are of varying sizes some are as large as your friend and some skinnier than even you). Now these riot police represent a solvent system (once again large is polar and skinny is non-polar).
Still with me? Ok here is where it gets interesting. The riot police want to force through the trees to the other side but in doing so they scare the crap out of you and your friend. So you start to push through the forest. You, being skinny are able to move through the trees easier, you don't get stuck and the trees can't grab onto you as easily, unfortunately your mate is not so lucky, he is struggling through the forest but can't get very far as the trees can't move aside for him very much and they grab him along the way.
Now the riot police, are still pushing through the forest too and just like your mate the bigger guys are moving more slowly but their sheer numbers are pushing your mate through and the skinnier riot police are overtaking you to the other side of the forest. You keep running through and eventually make out to the other side.
Now the speed with which you and eventually your mate made it depends on the number and size of the riot police. More large riot police moving through the forest will clear the trees down and allow you to move through the forest more easily as a result but you and your mate will like both just rush out so fast you both can't tell who won.
If there are more skinny riot police they are liable to overtake you both and make you both feel like losers. So you will have to wait for all the riot police to pass. But you, being skinny, will be able to move through the forest more easily so you will win but not in good time.
If the riot police were all roughly the same size somewhere in between you and your friend (indicating a good polarity for the solvent system) you should make it out before your mate but only enough that he doesn't lose sight of you in the trees and hate you for the rest of your life. If this is the case you might end up with your friend stuck in the forest and have to call for a gang of riot police to flush him out. (sometimes compounds get stuck on the column and need to be flushed out with a polar solvent).
The same is basically true for chromatography, the more polar the solvent system the slower it will run through the column (it is the mobile phase). But the more it will take up your compounds and force them through the column. If the solvent system is not polar enough the solvent will run through the column but not interact with the compounds on the column and the compounds will remain on the column for longer. If your compound is polar it will stick to the column more and therefore elute (i.e. come off the column) later. Inversely, if your compound is non-polar then it will not stick at all to the column and move very quickly through as the mobile phase passes.
Nov 15, 2009
RBF Teaches: Thin Layer Chromatography (TLC)
So, what does that mean? Well, for instance, let us assume we are performing a reaction in the lab. WOOOO! Now, how do we know when the reaction is complete? If your compounds are all colourless and no colour change occurs upon completion (as is usually the case) how can you know whether to stop the reaction? The answer my young friends is TLC! And Here is How we do it!
By taking a tiny sample of the reaction mixture (and I mean tiny, usually a drop is plenty) and comparing that to your starting material(s) you can determine whether the reaction is complete or not.
- TLC plates can usually be purchased as large square (20x20cm) sheets or as a large roll of silica (SiO4) (or aluminium oxide AlO4) adsorbed onto an aluminium backing sheet. You can also get TLC sheets with plastic or glass backing.
- From these large square sheets you can cut them using a sharp knife (mark the whole plate or a guillotine (cut the plates silver side up). I usually aim for my TLC plates to be 5cm long and 2cm wide, this gives me 40 plates per sheet. To cut the plates it is possible to mark with a pencil on the silica side (i.e. the white side) HOWEVER you must press very gently so that the silica is not etched with your pencil you only want to lightly glide the pencil over the silica.
- Once you have cut your plate it can be used for a TLC analysis. To begin with a straight baseline must be drawn across the bottom of the plate usually 0.5-1cm from the bottom and parallel to the base. This is your baseline and all of your spots will begin from this point so that there is no error. It should look something like this:
- Once you have this base line you can begin to plan your TLC. Usually, you spot at least 3 spots depending on the reaction. If for example, you have one starting material and a reagent which does not run on TLC the TLC would be spotted as follows 1. Starting material (SM) 2. Reaction mixture (R) 3. Co-spot (C, a spot on which both starting material and reaction mixture is spotted. This reduces the chance of a false positive due to a poor solvent front etc.). [MSG EDIT: The use of a co-spot lane is also helpful when your product and starting material spots have very similar Rfs. You will read about Rfs later] If you have more than one material or a reagent that runs then this spot should also be added as well as being spotted to the co-spot. Also, if you have a pure sample of the desired product then it is also a good idea to spot this too to ensure that your reaction mixture has the correct product being formed (this is also the case in which a known by-product that can be produced from the reaction). This should also be spotted on the co-spot.
- Having the plan in place you can now gently mark the TLC plate with a pencil. Remember, lightly so as not to scratch the silica. Mark the plate so that you can understand it and not be confused as well as marking it so that all the spots are evenly spaced from each other and not too close to the edge of the plate. A good example can be seen below:
- Once you have a sample that is reasonably well diluted (5mg/mL usually suffices) you can begin to spot the plate. [MSG EDIT: In general, aim for higher dilution, that is, lower concentration. Using high concentration spotting solutions leads to larger spots, which means poor resolution. If the concentration is too low, then you can simply spot more] Using a TLC spotter (these can be purchased or made simply by blunting the end of a small 21-23G needle) gently spot a small spot on the plate. This may take some practice. It is easiest to use a quick motion to avoid leeching of the solvent from the TLC spotter onto the plate this avoids overflow of the spot onto other spots. Do not over spot the plate. After you have run the TLC, if there is a large streak this means your spot was too concentrated. Your spots should appear as below:
- Time to run the TLC. This is reasonably straightforward. Place your solvent system in a small glass jar or beaker. It is a good idea to only have 0.5-1cm of solvent in the bottom of your jar so that the level sits just below the baseline of your TLC plate.
If you like [MSG EDIT: you should!] you can line the beaker with some absorbent paper (this will saturate the atmosphere of your beaker with solvent fumes allowing the plate to run quickly and smoothly. It is a good idea not to lean the TLC plate against the paper as it may leech solvent onto the plate). Place a watchglass or lid over the jar. Take your TLC plate by the top with a pair of tweezers and, after removing the lid of your jar, gently place the plate into the beaker try to make sure the plate is inserted levelly so that the solvent runs up the plate evenly.
- Once the solvent level reaches 0.5cm from the top of the plate you can remove the plate from the jar. Gently mark the plate at the solvent front (i.e. the level the solvent reached on the plate) with a pencil.
- Now you can develop your plate. This can be done with either UV light (most plates are fluorescent at 254nm) or using a dip. [MSG EDIT: UV light is especially useful as a visualisation tool if you know your product/starting material is aromatic or contains conjugated bonds]. To dip, simply take the chosen dip (selection of a dip depends on your compound) dip your plate quickly into the dip up to the solvent front and remove. Ensure that all the dip drips back into the dip jar to save on making up more dip and gently heat the plate with either a heat gun or on a heat plate. [MSG EDIT: Make sure your plate is free of solvent before dipping. I usually use a heat gun to blow dry the plate before dipping, and when I use a higher boiling solvent (such as ethyl acetate or methanol), I blow dry my plate for longer before dipping. A common mistake made by students is not heating the plate sufficiently. The colour of the spots depends on the dip you're using. When using a PMA (or Goofy's) dip, the spots should come up as dark blue spots on a green/blue background. Heat the plate until you see this. When the plate starts to turn dark blue (or just black), that's too much heating: stop. When using a permanganate dip, the spots should come up bright yellow against a pink/purple background. If the background goes yellow, then that's more than sufficient heating.]
- Now you can see your spots on the TLC plate. HOORAY! The next step is simply perfecting the method for your particular reaction.
- Find a solvent system that works for your particular reaction - This can often take some time. Basically, you want a system that is polar enough to move your spots up off the baseline but not take any spots off the plate. A good system to start with is 15% Ethyl Acetate (EtOAc) in Petroleum Spirits (PetSp) or Hexane. In this case the EtOAc is the polar solvent. If the spots are seen to move too far up the plate then lowering the amount of this polar solvent should lower the distance the spots travel. (See the OrganicOverdose explanation of this in the following post). Ultimately, you should have a TLC plate that looks something like this:
Here you can see that some SM remains and that the reaction mixture contains a new product. The co-spot shows both spots which indicates that the final R spot is not a false positive. It is usually a good idea to try to get the topmost spot to fall below halfway up the plate. (Reasons for this will come up later). [MSG EDIT: As a rule of thumb, the spot you're trying to isolate should be just less than 1/3 up the plate, ie Rf ~0.3)
To measure the Retention Factor (Rf) of the spot is as follows:
Rf = distance of spot/distance of solvent front
the solvent front is the distance you let the solvent move up the plate. This means that no matter how far up you let the solvent front move the Rf of a particular spot should remain the same (to a degree). This means that it is very important to mark the solvent front when you have finished running the TLC and before you begin to develop the TLC.
- Once you have all these points down pat you can run a TLC every reaction to make sure that the reaction is complete.
- Mark your plates gently with a pencil (don't use pen: it will be very embarrassing)
- Spread your spots out evenly and leave a good distance from the side of the plate.
- Don't overspot the plate. If you have a large streak on the plate it is a good indication of overconcentration. [MSG EDIT: Remember, TLC is a visualisation tool for your reaction. As long as you can see the spots, it's fine, so there's no need to make spots extra intense. Less intense and smaller spots means better resolution, which is always good, especially if you have spots which are very close running]
- Don't overfill your TLC jar above the baseline of the TLC plate.
- Don't lean your TLC plate against the absorbent paper in the TLC jar.
- Make sure your solvent system is good you want decent separation between spots (this will be covered at a later date)
- Be sure to mark your solvent front before developing your TLC.
- Don't leave your plate in the dip. It is a quick dip and then removal.
- When developing your plate under UV use a pencil to mark in the spots that appear under UV light.
Please Note that the video has no sound at present but we will add a commentary to the video soon.
[MSG EDIT: If you're an undergrad who wants to ask questions about anything on this post or laboratory techniques in general, feel free to post them on the comments section. OO and I (and I'm sure grad students around the world who visit here) are more than happy to answer your questions and give you a helping hand]
Nov 12, 2009
Breaking Bad
This show is awesome. It has everything you could possibly want in a show.
- It has a great plot and storyline - A career chemist turned high school teacher gets lung cancer and decides to manufacture crystal meth on the side.
- Great comedy
- Great action
- Great characters
- CHEMISTRY YAY!
If you haven't seen this show yet I suggest you get watching as it is awesome! I have posted a small clip that I think sums up how awesome this show is whilst showing the cool chemistry side of it too.
Note the use of HF in the bathtub LAWLZ (You'll have to watch the show to find out just why they had to dispose of a body named Emilio (P.S. See A Night At The Roxbury EMILIOOO!)) Season 3 starts March 2010 I think.
Nov 10, 2009
Further Education for Chemistry Undergrads
Hopefully, if we can figure it out we will be putting youtube links of some experiements that the second year undergrads do in the second semester. We will probably source some of the other reactions from first and third year as well to show basic and advanced techniques.
Nov 8, 2009
Superfreakonomics
The success of the Freakonomics series made me think: are there any chemistry books written for the general public that has received such high acclaim? If so, I'd certainly like to know what they are. The Freakonomics series are hugely popular. On the day I bought Freakonomics (the original) four years ago, it was in the top 10, if not top 5 (memory fails me) bestsellers. Today, according to the NY times, Freakonomics is number 1 paperback non fiction, and Superfreakonomics is number 2 hardcover non fiction. When did a popular science (and in particular, chemistry) book make such a big splash?
Nov 6, 2009
Pros and Cons of Two Organic Chemists Dating - Add your experiences
You can roll over in the middle of the night and ask "What do i distill TMSCl over?"
You will always be able to understand each others frustrations: "I lost 3 months work today because it fell in the oil bath" or
"I just racemised my product after 20 steps!"
You won't have to explain jargon such as NMR, enantiomers, flash chromatography, GC-MS etc.
They can proof read your experimental / publications etc.
Cons
You can't have a break from chemistry at home.
You may compete for the same job / grant proposals
After finishing your PhD(s), you are usually expected to do a postdoc overseas. Trying to find a postdoc for both in the same place is difficult.
You may be, or end up working together in the same building / lab and see each other all day.
Trapped in a chemistry circle. Possible limited associations with normal people.
Nov 4, 2009
Iron Catalysis
Nov 3, 2009
JOC Fail
So it's good to see when someone goes above and beyond to supply the journal with a nice picture. In this case, a JOC article.
I was scanning through my newly set up RSS feed for JOC ASAP articles and saw this little gem that I had to share here. I have no idea what the article is about other than building aromaticity in a ladder-like structure.
Pyrazinacenes: Aza Analogues of Acenes
Gary J. Richards, Jonathan P. Hill, Navaneetha K. Subbaiyan, Francis D’Souza, Paul A. Karr, Mark R. J. Elsegood, Simon J. Teat, Toshiyuki Mori and Katsuhiko Ariga
- Why would you include a picture of yourself in a chemical synthesis?
- Why would you send the picture in to a reputable publication like JOC?
- Why didn't you make sure the picture was accurate before sending it in to JOC?(N.B. Final structure is almost definitely missing some nitrogens from the second from top ring system).
- You shouldn't advertise the fact that you don't know how to safely operate a step ladder.
But regardless, I must thank the author, you brightened up an otherwise dreary day. HILARIOUS!!!
Nov 1, 2009
Breaking News
Oct 29, 2009
Evil Lab Challenge
It consists of the selection of a particular song (usually pop) which is then put on the lab music system and put on repeat. The song is then left to play consecutively until one person remains in the lab. However, as some daily duties require absence from the lab (e.g. toilet breaks, literature searches etc.) a tally is kept of each song listened to. This firstly makes sure you aren't tuning the song out but also makes sure you return to the lab.
As it was today, the song choice was Modern Talking's "You're my heart, you're my soul" (see previous post). Unfortunately, I found this song hidden in the depths of our lab music system's archives. I wish I hadn't.
It was HORRIBLE!!! We listened to that song from 10:00AM through to 5:00PM. I had to leave the lab several times, unfortunately the song could still be heard in the office. As a result I believe I have a tumour. The song's play length is 3:49. This means that the song was played approximately 110 times straight throughout the day. DEAR GOD!
At first, I thought it was OK, I was singing along to the music, but in the end I cracked. I still have the song running through my head. Apparently, tomorrow will be all German music all day, but not the same song over and over.
Oct 28, 2009
Ether peroxides!
Sure enough, there was my starting material and all its familiar peaks, but I also saw two 2:1 ratio quartets at ~5 and ~4 ppm respectively. What the...
These peaks also reminded me of the strange peaks that I saw in the crude NMR spectrum of my previous reactions using the same compound. I knew it wasn't a degradation product of my starting material, so I simply thought it was something from the reagents and solvents. But when the same peaks kept turning up when I changed solvents and reagents, I knew something didn't really make sense. The only things common between those reactions were the starting material, and the work up procedure, and that's when I suspected that diethyl ether peroxides were in my crude.
This morning I checked my bottle of ether for peroxides using the KI solution test, and sure enough, there it was. Shaking a bit of my ether with a solution of KI resulted in a pinkish orange organic layer (due to the peroxides oxidising the iodide ions to iodine), and a yellow water layer (due to the I3- ion). Testing various bottles around the lab, it seems (from qualitative observations) that my bottle actually had much more peroxides than others. I guess it's probably due to my habit of having my own bottle of ether. B, probably due to the nature of his chemistry, almost never uses ether since it's not polar enough. P just grabs a bottle of ether on the shelf whenever he needs it, so each of the bottles on the shelf roughly gets the same exposure to air and light. Since I have my own bottle, my ether gets much more exposure to the elements than the other bottles. And since I've been doing <10mg reactions, the small amounts of peroxides show up very well in my crude NMR, as I don't necessarily scale down work up procedures proportionally. If I did I would be extracting with 0.5mL to 1mL of solvent which really isn't practical. B and I washed every single last drop (well not really) of diethyl ether in the lab with KI solution, then washed the ether with sodium thiosulfate solution. Drying with sodium sulfate then distillation gave (hopefully) peroxide free diethyl ether. The question is: why did my starting material, which was columned and dried and stored under argon in the freezer, have diethyl ether peroxides? I think it's because I wash my NMR tubes with water, acetone and diethyl ether successively before drying in a warm oven. The ether I used must have had peroxides. Either that or it was from the solvent used in the column in which I purified the starting material in the first place. All the more reason to change the purification protocol of this compound from an ethereal solvent system to a hexanes/EtOAc one. Unless an ethereal solvent system gives improved separation over a hexanes/EtOAc system, or unless there are problems with volatility, why use an ethereal solvent in the first place. Sure, you can rotavap the stuff off a bit faster, but it's so much more expensive.
Oct 27, 2009
Modern Talking
Thankfully, I wasn't alive at the time of these SUPER tracks. But Dieter Bohlen, the blond guy with slightly less makeup made Billions of Deutschmark on this kind of crud and is still a massive celebrity in Germany. NUTS!!!! (He now wears more makeup).
Thomas Anders, the scarily androgenous guy in these clips is HILARIOUS and I recently dug up that he had a concert in July THIS YEAR!!! ZOMFG! Who the hell pays for this stuff??!!
Anyway, that was the highlight of my day today and I thought I would share that small amount of joy with whoever reads this.
Oct 26, 2009
Student Reports
Don't get me wrong. Some students are a delight to teach, fun to talk to and very intelligent. But there is always another end to the spectrum. Where the student ignores your instructions, cuts themselves and bleeds all over the lab. Or simply falls asleep in the fume hood (ask MSG). Anyway, it might seem that with these students that their reports will follow a similar pattern in which they neglect to read the instructions on writing up the report.
However, this is usually not the case. Where you may have a sociable, smart student in the lab it is often the case that they are sloppy with their reports and neglect to read the instructions carefully. Which is a shame as they are only marked on their reports. Conversely, the crazy ignorant student somehow garners enough knowledge of the English language to produce a decent report.
This isn't the case for all the students and is just an extreme case but it often makes me laugh, then cry then repeat the process as each surprise appears. I hate to admit it but by the end of this marking session I will probably be a deranged quivering heap incapable of human conversation. This is most likely also going to be due to the lack of assistance we have from teaching staff who lump the pracs on us and tell us to mark them without a marking scheme. I mean, sure we know how to run the prac, but c'mon, that means we have to actually do some work and figure out some answers. Seriously, don't these guys know we have blogs to write and facebook to check.
Just to make matters worse I have to feel sorry for the students who get poor marks so that I go back over the damn thing to see if I missed something only to find out that 'Nope, he's just an idiot' or 'nope they didn't just fill out the answer sheet and now I have to go read through the whole thing to find their answer'. I swear to god if the chemicals don't kill me this probably will or at least age/jade me to something more like the PhD students I remember coming through as an undergrad.
Oct 25, 2009
Undergrads' shenanigans
Asleep at the fumehood
Why would you bother turning up to labs if you're just going to fall asleep. And is there a worse place to fall asleep than with your face planted on the bench inside the fumehood? "Dude, wake up, you can't sleep there" I exclaimed, but to no avail. "Hey, you get up, you can't sleep there" I shouted this time, but he didn't respond. By then another student required my attention, but fortunately for our sleeping student here, he was awake by the time I got back to him, about to physically pick him up and get him out of the lab. Fortunately it was only a flash column being run in his hood, nothing too dangerous.
Recrystallisation or evaporation?
The students really seemed to be confused as to what recrystallisation meant. As the title suggests, they thought that by simply dissolving the crude product and evaporating it, the Law of conservation of mass would somehow not hold true for the tiny piece of the universe inside their conical flask, and the brown impurity would simply disappear.
One of these students was both arrogant and ignorant. "Tutor, how do I evaporate this solvent faster under a stream of nitrogen?"
I didn't remember this being part of the procedure, so I asked "why do you need to do this?"
Student: "I'm trying to evaporate the solvent and I need to do it faster"
Me: "But why are doing this?" (By then I realised he was trying to do a recrys, but was trying to ask him questions so that he would understand the error of his ways)
Student: "I need to evaporate this solvent but it's very slow. I just need to do this ok? Can you just tell me how to do it faster?"
Me: "But stop for a sec, why are you doing this? What is the point of dissolving something and just evaporating the solvent?"
Student: "Can you just tell me how to evaporate this faster? That's all I need to know ok?
Me: "You're trying to do a recrystallisation, so what you need to do is dissolve it in minimum amount of boiling methanol and then let it cool slowly. You DON'T want to just evaporate all the solvent."
Student (dismissively): "Are you sure? Can you just tell me how to evaporate the solvent?"
Me: "Look, you can do whatever you like, but at the end of the day, the melting point doesn't lie. If you don't do it properly, then you're only kidding yourself because when the lab technician runs your melting point it's going to be horrendous."
Student finally realises (or did he?) his mistake but walks away without a word. He does the recrystallisation as I requested.
Rouding
Each of the tutors was responsible for marking the reports of a particular experiment for the course. I was marking one where they had to find the ratio of oxygen uptake per mole of a particular transition metal. Now everyone knows the answer was 1 oxygen molecule to 2 metal ions. As one might expect, not every student obtained experimental data that corresponded to this. Here are some of the most frustrating explanations... or the funniest explanations... and if you've been marking reports for the last 5 hours it's definitely the former.
"The ratio obtained was 1.4 to 1. Since 1.4 is closest to 1.5, the ratio can be taken to be 1.5 to 1. Therefore the ratio is 2 to 1 since 1.5 should be rounded to 2."
"The ratio determined was 2.7 to 1. Since 2.7 is not quite 3 , the ratio is therefore 2 to 1"
"The amount of oxygen was 0.0018, ~0.002. The amount of {metal} is 0.0014, ~0.001. Therefore the ratio is 0.002/0.001 = 2.0" (FYI 0.0018/0.0014 is 1.3)
Referencing
How awesome is this for a reference to a melting point
I told the students specifically that wikipedia is not a valid reference. So how surely this would be ok right?
Oct 24, 2009
Fantastic scenery in organic chemistry
For me, it is so pleasing to the eye when you load a flash column with a solution of brown crude product from a reaction, and the brown junk gets stuck at the top. Of course, that joy is short lived if you find out that you failed to achieve good separation, or that the brown junk accounted for most of the weight of your starting material...
More visually spectacular however is the colour of a sodium benzophenone still. For those not familiar with this, the sodium and benzophenone system is used to dry (remove trace amounts of water from) a range of organic solvents, such as diethyl ether, benzene, tetrahydrofuran (THF). Thinly rolled (or drawn) sodium is added to the solvent along with benzophenone. When water is still present in the solvent, the solvent/benzophenone mixture is yellow. However, once the solvent is completely dry, the colour turns to a deep deep blue colour. The sight of a deep blue solution of THF with bits of metallic silver sodium bobbing up and down as the solvent refluxes brings tears to my eyes. Well not really, but it's a pretty awesome sight.
My all time favourite (for now) is in distillation of reagents. I had to distill TMSOTf the other day. Actually you'd think it shouldn't be yellow considering it was stored in an ampule. In any case, I distilled the stuff across into a Schlenk flask nice and clear, leaving the yellow residue behind. Beautiful!
Oct 20, 2009
Walking around on two broken legs
As it is we are a still alive but all three of us are hobbled. I personaly have named the double blisters on both my feet and look forward to having some intimate alone time with them for the next week or so.
P on the other found a tick today and decided that the best method of tick removal is nitric acid. After some convincing we got him to just pull it out but we couldn't stop him for sending the little fella into a nice little spa bath of nitric. Needless to say the tick died.
Anyway, finally managed to crawl out of bed this morning and put some shoes on so I can get in the lab. After a bit of literature searching I found the reaction I am going to do today and will hopefully lead me to an improved method for my drug. YAY! Just me and J in the lab today methinks.
Oct 16, 2009
Welcome to RBF
Looking forward to our 'real' first post!